ABB | DC Fast (24 kW, compact destination charger)
Terra DC Wallbox
Compatible. Connect and manage your Terra DC Wallbox with Plugchoice over OCPP, alongside any other brand.
Where to buy
Shops we track selling this charger, cheapest known price first. Prices are read from public listings and exclude installation unless noted.
No tracked shops for this charger yet.
Specifications
Each value shows its source and the date it was read. A check marks data confirmed by a second, independent source.
Identification
- Product segment
- DC Fast (20-50kW)✓✓
- Lifecycle status
- Legacy✓✓
Technical Specifications
- Weight
- 60✓✓
- Charging capacity
- 24 kW✓✓
- Number of outlets
- 1 or 2✓✓
- Operating conditions
- -35C to +45C, linear derating to +55C (NA datasheet); EU spec doc: -40C to +45C no derating, 80% output 45-50C, 60% output 50-55C, humidity 5-95% non-condensing, altitude up to 2500m, noise <60dB✓✓
- Current type (AC / DC)
- DC✓✓
Physical
- Height (mm)
- 770✓✓
- Width (mm)
- 584✓✓
- Depth (mm)
- 300✓✓
- Mounting options
- Wall-mounted (standard) or free-standing pedestal (optional)✓✓
Electrical
- Number of phases
- 1 or 3✓✓
- Rated voltage
- 208-240 VAC +/-10% (1-phase) / 480Y/277 VAC +/-10% (3-phase, NA); 400 VAC +/-10% 3P+N+PE (CE/EU)✓✓
- Rated / max output current
- 60 A (DC output current)✓✓
- Grid frequency
- 60 Hz (NA); 50 Hz or 60 Hz (CE/EU)✓✓
- Max upstream fuse / breaker
- 125 A (1-phase NA) / 50 A (3-phase NA)✓✓
Connector
- Connector type
- CCS1, CHAdeMO✓✓
Connectivity
- WiFi
- Not stated either way by ABB; only GSM/4G modem and 10/100 Base-T Ethernet are documented, ENERGY STAR registry lists only Cellular.✓✓
- Cellular (4G/LTE)
- GSM / 4G modem✓✓
- Ethernet
- 10/100 Base-T Ethernet✓✓
- OCPP versions
- OCPP 1.6✓✓
- Backoffice / CSMS compatibility
- ABB Ability Connected Services / OCPP back-end integration; web tools for statistics, configuration, access management, remote diagnostics✓✓
Safety detail
- Built-in RCD / RCBO type
- Upstream RCD type A (or higher) required, with rated residual operating current not exceeding 30 mA (<=30 mA, not >=30 mA); onboard design limits DC ground fault current to 6 mA or less at AC side upstream so RCD type B is not required unless local code demands it.✓✓
- IP rating
- IP54✓✓
- IK rating
- IK10 (enclosure), IK08 (HMI/touchscreen)✓✓
HMI / UX
- Display
- 7-inch full color, daylight readable touchscreen✓✓
Installation
- Indoor / outdoor
- Indoor and outdoor✓✓
Compliance extra
- Standards (full list)
- UL 2202 Ed. 2, CSA C22.2 No. 107.1-16, FCC Part 15 Subpart B Class A/B, ENERGY STAR (NA datasheet). UL variant leaflet adds EN 61851, EN 62196, CHAdeMO 1.2, DIN 70121, ISO 15118, IEC 61000-6-3. EU spec doc: EN 301489 series, EN 61000-6 series, EN 61000-3-11/12, IEC 61851-21-2 (EMC); EN 60529, EN 61851-1, EN 61851-23, EN 62311, IEC 61851-1, IEC 61851-23 (LVD/safety); EN 301511, EN 301908-2, EN 300330 (RED)✓✓
Market & positioning
- Markets sold / certified
- North America (US/Canada): UL 2202, CSA C22.2 No. 107.1-16, FCC Part 15, ENERGY STAR; Europe (CE models): EMC/LVD/RED directives, EN 61851, EN 62196✓✓
Certification & compliance
- CE / UKCA marking
- CE certified (EU models), by an independent notified body e.g. TUV Rheinland✓✓
- Declaration of Conformity (link)
- Required per unit/family for CE (self-declared against EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU, plus RoHS 2011/65/EU)✓✓
About this page
ABB and the ABB logo are trademarks of their respective owner. All other names, logos and trademarks are the property of their respective owners. This page is published independently by Plugchoice and is not affiliated with, endorsed by or sponsored by ABB. Every detail about ABB was taken from publicly available sources and was accurate to the best of our knowledge on the date shown. Specifications and features change often, so please confirm the current details with the manufacturer before relying on them.