ABB | DC Hyper (200-360 kW, depot fleet charging, cabinet)
HVC360 (HVC200/HVC300/HVC360)
Compatible. Connect and manage your HVC360 (HVC200/HVC300/HVC360) with Plugchoice over OCPP, alongside any other brand.
Where to buy
Shops we track selling this charger, cheapest known price first. Prices are read from public listings and exclude installation unless noted.
No tracked shops for this charger yet.
Specifications
Each value shows its source and the date it was read. A check marks data confirmed by a second, independent source.
Identification
- Product segment
- DC Hyper (350kW+)✓✓
- Range / variants
- HVC200HVC300HVC360✓✓
- Lifecycle status
- Active✓✓
Technical Specifications
- Weight
- 950✓✓
- Charging capacity
- 200-360 kW✓✓
- Number of outlets
- 1 to 4✓✓
- Operating conditions
- -30C to 55C with derating✓✓
- Standby consumption
- 130 W✓✓
- Current type (AC / DC)
- DC✓✓
Physical
- Height (mm)
- 2180✓✓
- Width (mm)
- 1170✓✓
- Depth (mm)
- 770✓✓
- Mounting options
- Floor mounted✓✓
Electrical
- Number of phases
- 3✓✓
- Rated voltage
- 400 V AC +/-10% (CE) / 480 V AC +/-10% (NA)✓✓
- Grid frequency
- 50 Hz +/-4% (CE) / 60 Hz +/-4% (NA)✓✓
- Peak withstand / short-circuit current
- 25 kA (CE) / 65 kA (NA)✓✓
- Surge protection level
- Type 2✓✓
Connector
- Connector type
- CCS1, CCS2, Panto Down, Panto Up✓✓
Metering
- Meter accuracy class
- Eichrecht (CE, select dispensers)✓✓
Connectivity
- Cellular (4G/LTE)
- Yes✓✓
- Ethernet
- Yes✓✓
- Plug & Charge (ISO 15118)
- ISO 15118 supported for vehicle comms/Autocharge with EIM (external identification); certificate-based Plug & Charge not explicitly stated in the datasheet.✓✓
- OCPP versions
- OCPP 1.6✓✓
- Backoffice / CSMS compatibility
- OCPP 1.6 JSON✓✓
Safety detail
- Earth fault protection
- Supports TN-C, TN-C-S, TN-S, TT earthing systems✓✓
- Overvoltage category
- III✓✓
- IP rating
- IP54✓✓
- IK rating
- IK10✓✓
- Pollution degree
- Class 3 (outdoor) / Class 2 (indoor)✓✓
HMI / UX
- LED status indicator
- Yes✓✓
Installation
- Indoor / outdoor
- Indoor and outdoor✓✓
- Installation style (backplate / direct mount)
- Floor mounted✓✓
Compliance extra
- Standards (full list)
- Safety: IEC 61851-1 ed 3, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, UL 2202, CSA 22.2; also EMC: IEC 61851-21-2; Electrical Safety: IEC 61439-7 (CE) / NEC NFPA 70 (NA); Additional: IEC 60529 (cabinet IP rating)✓✓
Market & positioning
- Markets sold / certified
- Europe (CE); North America (UL 2202, CSA 22.2)✓✓
Media & assets
- Official datasheet (link)
- https://library.e.abb.com/public/ec2bc0ec97114f62806cda649cc72b44/HVC360_Datasheet_Public_V2-3_Global_EN.pdf.pdf✓✓
About this page
ABB and the ABB logo are trademarks of their respective owner. All other names, logos and trademarks are the property of their respective owners. This page is published independently by Plugchoice and is not affiliated with, endorsed by or sponsored by ABB. Every detail about ABB was taken from publicly available sources and was accurate to the best of our knowledge on the date shown. Specifications and features change often, so please confirm the current details with the manufacturer before relying on them.