Each value shows its source and the date it was read. A check marks data confirmed by a second, independent source.
Identification
- Brand
- KEBA✓✓
- Manufacturer / OEM
- KEBA✓✓
- Country of origin / design
- Austria✓✓
- Product segment
- AC Residential/Commercial✓✓
- Range / variants
- e-series / b-series / c-series / x-series; Type 2 socket or 6m cable✓✓
- Lifecycle status
- In production✓✓
- Form factor
- wallbox✓✓
Technical Specifications
- Weight
- 4.8-7.8 kg (variant dependent)✓✓
- Charging capacity
- 22 kW✓✓
- Number of outlets
- 1✓✓
- Communication protocol
- OCPP (optional), Modbus (external meter integration, optional), UDP (optional)✓✓
- Network interfaces**
- Ethernet (LSA+ terminals, 10/100/1000 Mbit/s) + RJ45 debug port; USB 2.0 Type A; WLAN 802.11 b/g/n 2.4GHz; optional GSM 3G/UMTS✓✓
- User interfaces
- RFID card reader (optional), key-operated switch (optional), LED status bar, optional MID energy meter LED display✓✓
- Internal energy meter
- Optional✓✓
- Supported grid types
- TN;TT;IT✓✓
- Power connection
- 230V 1-phase (e-series) or 3x230V/400V 1-phase or 3-phase (b/c/x-series); rated current configurable 10/13/16/20/25/32A; 50Hz✓✓
- Safety
- IP54; IK08 (except cylinder lock); Protection class I; Overvoltage category III (EN 60664); Internal RDC-DD DC fault monitoring >=6mA; Rated short-time withstand current <10kA (EN 61439-1); external Type A RCD required✓✓
- Operating conditions
- -25C to +50C (16A variant) / -25C to +40C (32A variant); storage -25C to +80C; humidity 5-95% non-condensing; altitude max 2000m; max temp change 0.5C/min✓✓
- Standby consumption
- 2-4 W idle (series dependent)✓✓
- Recommended mounting height
- 1.2 m (charging socket height)✓✓
- Compliance
- LVD 2014/35/EU; EMC 2014/30/EU; RED 2014/53/EU; RoHS 2011/65/EU; WEEE 2012/19/EU; MID 2014/32/EU✓✓
- Current type (AC / DC)
- AC✓✓
- Charging mode (IEC 61851)
- Mode 3✓✓
Physical
- Height (mm)
- 495✓✓
- Width (mm)
- 240✓✓
- Depth (mm)
- 163✓✓
- Enclosure material
- Plastic housing✓✓
- Color options
- RAL 7004 (signal gray) / RAL 7016 (anthracite gray); RAL 9010 (pure white) / RAL 7016 (anthracite gray)✓✓
- Mounting options
- Wall;Pole✓✓
Electrical
- Number of phases
- 1 or 3✓✓
- Rated voltage
- 230V / 3x230V/400V✓✓
- Rated / max output current
- 32 A✓✓
- Min adjustable current
- 10 A✓✓
- Max power 1-phase
- 7.4 kW✓✓
- Max power 3-phase
- 22 kW✓✓
- Grid frequency
- 50 Hz✓✓
Connector
- Connector type
- Type 2✓✓
- Socket / cable / shutter
- Optional✓✓
- Shutter option
- Optional✓✓
Metering
- Meter accuracy class
- Class B (EN 50470-1/-3), MID optional✓✓
- Metering accuracy (%)
- Class B (EN 50470-1/-3); min current 0.15A, reference current 3A, max current 16/20/32A; 10,000 pulses/kWh test mode✓✓
- MID certified
- Optional✓✓
Connectivity
- WiFi
- Yes✓✓
- WiFi bands / standard
- IEEE 802.11 b/g/n, 2.4 GHz✓✓
- SIM type
- Mini-SIM (2FF), industrial/M2M recommended✓✓
- Ethernet
- Yes✓✓
- RFID / NFC
- Yes✓✓
- Local API (Modbus / REST)
- Modbus TCP✓✓
- Backoffice / CSMS compatibility
- Generic OCPP-compatible CSMS/backend (any OCPP-based system); no proprietary backend required✓✓
- OEM onboarding / API docs (link)
- Yes: KEBA publishes a KeContact P30 Modbus TCP Programmer's Guide✓✓
Smart / load management
- Dynamic load balancing
- Yes✓✓
- Group / static load balancing
- Yes, master/slave local load management; x-series controls up to 15 c-series units✓✓
- Load-balancing measurement source
- External energy meter (Modbus integration)✓✓
Safety detail
- DC leakage protection
- Internal RDC-DD, >=6mA DC residual current detection; external Type A RCD required (not built-in)✓✓
- Built-in RCD / RCBO type
- RDC-DD (DC 6 mA)✓✓
- Earth fault protection
- External RCD Type A required (not integrated); internal RDC-DD provides 6mA DC fault monitoring✓✓
- Overload / overcurrent protection
- Rated short-time withstand current <10kA (EN 61439-1); line circuit breaker sized externally to match DIP-switch current setting✓✓
- Temperature sensors
- Yes, internal; triggers automatic power reduction on overheating✓✓
- Insulation class
- Class I✓✓
- Overvoltage category
- III✓✓
- IP rating
- IP54✓✓
- IK rating
- IK08✓✓
HMI / UX
- Display
- Optional, on MID energy-meter variants✓✓
- LED status indicator
- Yes, 4-segment LED status bar (S1-S4)✓✓
Installation
- Wire terminal type
- Spring-type (push-in) terminals✓✓
- Tightening torque
- 2 Nm (connection panel cover screws)✓✓
- Indoor / outdoor
- Indoor & Outdoor✓✓
- Installation style (backplate / direct mount)
- Wall-mounted (surface or flush cable feed) or floor-mounted column✓✓
Compliance extra
- Standards (full list)
- IEC 61851-1; EN 60664; EN 61439-1; EN 62196-1; SAE-J1772; VDE-AR-E 2623-2-2; EN 50470-1/-3; MID 2014/32/EU; RED 2014/53/EU; RoHS 2011/65/EU; WEEE 2012/19/EU; LVD 2014/35/EU; EMC 2014/30/EU✓✓
Optional / non-technical
- Max. AC IN wire size (mm2)
- 2.5-16 mm2 (16A variant) / 6.0-16 mm2 (32A variant), depending on cable/install type✓✓
Market & positioning
- Apparent product focus
- Legacy AC wallbox line: existing installations, professional charging networks, projects relying on proven technology (KEBA positions P40/P40 Pro as the current generation)✓✓
Certification & compliance
- CE / UKCA marking
- CE✓✓
Media & assets
- Official datasheet (link)
- https://www.go-e.sk/wp-content/uploads/2019/09/kecontactp30technicaldata_dben.pdf✓✓
About this page
KEBA and the KEBA logo are trademarks of their respective owner. All other names, logos and trademarks are the property of their respective owners. This page is published independently by Plugchoice and is not affiliated with, endorsed by or sponsored by KEBA. Every detail about KEBA was taken from publicly available sources and was accurate to the best of our knowledge on the date shown. Specifications and features change often, so please confirm the current details with the manufacturer before relying on them.